Search

Victron Lynx Shunt VE.Can

SKU: VT-LYN040102100

£370.00 Inc. VAT

Victron 5 Year Warranty

Description

Victron Lynx Shunt Ve.canVictron Lynx Shunt VE.Can

The Victron Lynx Shunt VE.Can  is an advanced DC monitoring component that is part of Victron Energy’s modular Lynx distribution system. It is designed to monitor the current, voltage, and state of charge (SOC) of your battery bank and provide detailed insights for efficient system management.

Key Features

  1. Integrated Shunt:
    • Contains a 500A shunt for precise current measurement.
    • Measures battery charge and discharge currents with high accuracy.
  2. Battery Monitoring:
    • Tracks key parameters such as:
      • Battery voltage
      • Battery current (charge and discharge)
      • State of Charge (SOC)
      • Time remaining
    • Essential for maintaining battery health and optimizing performance.
  3. VE.Can Communication:
    • Communicates with Victron’s Cerbo GX, Color Control GX, or other GX devices for real-time system monitoring.
    • Data can be viewed on the Victron Remote Management (VRM) portal via internet connection.
  4. Modular Design:
    • Part of the Lynx distribution system, integrates seamlessly with:
      • Lynx Power In (for managing power input from multiple sources).
      • Lynx Distributor (for DC load distribution with fuse protection).
  5. Built-in Monitoring Capabilities:
    • Includes LEDs for system status and potential fault identification.
    • Easy to integrate with other Victron components for a complete monitoring solution.
  6. Firmware Updates:
    • Supports firmware updates via connected GX devices, ensuring up-to-date performance and compatibility.

Applications

  1. Off-Grid Systems:
    • Monitor and manage battery banks in off-grid solar setups.
  2. Marine and RV Systems:
    • Provides real-time insights into battery performance for boats, yachts, and campervans.
  3. Hybrid Systems:
    • Optimizes battery usage in hybrid grid-tied setups.
  4. Industrial and Backup Power:
    • Ensures reliable performance of battery banks in critical systems.

Installation and Setup

  1. Integration:
    • Install in-line with the battery bank’s negative terminal.
    • Connect to other Lynx components for a modular and streamlined setup.
  2. VE.Can Connection:
    • Use standard VE.Can cables to connect the Lynx Shunt to a GX device.
    • Configure settings via the VictronConnect app or a GX device interface.
  3. Monitoring:
    • Data is accessible locally on a GX device or remotely via the VRM portal.

Lynx System Overview

The Lynx Shunt VE.Can is typically paired with:

  1. Lynx Power In: Combines power inputs from multiple sources.
  2. Lynx Distributor: Distributes DC power with individual fuse protection and monitoring.
  3. Battery Bank: Works seamlessly with Victron-compatible batteries, including lithium-ion (LiFePO4).

Why Choose the Lynx Shunt VE.Can?

  • Accurate Monitoring: Essential for extending battery life and preventing over-discharge.
  • Seamless Integration: Fully compatible with the Victron ecosystem.
  • Remote Management: Monitor your system from anywhere using the VRM portal.
  • Future-Proof: Firmware updates ensure long-term compatibility and performance.

Additional information

Weight 0.2 kg
Brand

Victron

Specification

Technical Specifications

  • Shunt Rating: 500A (continuous)
  • Voltage Range: 8-70V DC
  • Communication Protocol: VE.Can (Victron Energy’s proprietary CAN bus protocol)
  • Connection Points: M8 connections for robust and secure wiring.
  • Dimensions: Compact and modular to fit into the Lynx distribution system.
  • Operating Temperature: -40°C to +60°C (-40°F to +140°F).

Downloads

Quick and efficient access to product specifications, user manuals, and other relevant documentation.

Victron Lynx Shunt Ve.can Datasheet Lynx Shunt VE.Can

If you don’t see the information your looking for or your inverter is not on the list, please get in touch at [email protected].

Returns Policy

We want to ensure that you are entirely happy with the products purchased from us.  But in the event that you need to return  an item all we ask is that you follow our returns policy below to ensure products are traceable and returned safely.  If you do not adhere to our policy then your rights to a refund will be revoked.

We believe our returns procedure is very fair and in simple terms, if the items are returned in the same unused conditions as you would expect to receive a new items then we will refund the full cost of the item(s) without quibble.

Returns Procedure

In order for us to accept a return or offer a refund, we will need to be contacted first. You can contact us at the address below, by telephone or email.  Please see the details below.

Failure to contact us prior to return will result in your right to a refund and/or exchange to be withdrawn.

Refund Policy

You have up to 14 days to contact us for a return and a further 14 days for us to receive the item(s).

Returning Goods

Once you have contacted us, we will issue a returns number that should be clearly displayed inside the packaging.  The original packing should be used when returning goods to us.

Some of the items we supply are classed as hazardous goods (Class 9) and MUST be identified correctly for shipping.  We may insist that we arrange proper shipping back to our warehouse.

Who Pays The Carriage Cost?

Plain and simply, if you wish to return an item you’ve purchased incorrectly or don’t want.  Then, you will have to pay the carriage costs.  In some cases due to the hazardous nature of some products we will insist that we arrange return.  We will only charge you our cost to return the item.

If, we’ve made a mistake and supplied the wrong item, then we will arrange collection at our cost.
For any warranty claims after 14 days of receipt of an item, you will have to bear the cost of carriage back to our designated UK service centre.

Improper Returns

If you return a product in contravention of this policy, and you do not have any other legal right to a refund or exchange

(1) We will not refund the purchase price or exchange the product;

(2) We may retain the returned product until you pay to us such additional amount as we may charge for re-delivery.

(3) If we do not receive payment of such additional amount within 14 days of issuing a request for payment, we may destroy or otherwise dispose of the returned product in our sole discretion without any liability to you.

(4) If the product has been returned damaged and is deemed to be hazardous, where possible we will take photographic evidence before disposing of the item safely.

Cancellations & Amendments

Please ensure you check you have ordered the correct products

Will not be held liable for any wrong orders placed on your behalf. We will, however, ensure if you do make a mistake, we are on hand to rectify any errors. From the point of fulfilment, we will do our best to make any amendments you require, but will not be held accountable if this is not resolved at the time of dispatch. Unfortunately, you will be required to adhere to this policy in order to qualify for a refund and/or exchange.

Delivery

We will despatch your order as soon as possible.  For larger items pallet delivery times may be extended to 2-3 days for stock items.  We will notify you of your delivery either by email or contact number provided.  Please make sure that you are prepared to receive the delivery as re deliveries my incur additional costs.  If the items are returned to us due to none delivery or none acceptance the delivery charges incurred will be deducted from the refund value.

Our registered place of business is:
Skyenergi
Shaw Cross Business Park
Shaw Cross Court.
Dewsbury. WF12 7RF

You can contact us at the above address.
Telephone: 01924 438238
eMail: [email protected]

Our terms and conditions & returns policy do not affect your statutory rights .  

Please note the delivery charges you paid for the purchase of goods is not necessarily the cost for none delivery or returned/exchanged goods. 

Product Advice

1. This equipment may only be installed, operated and maintained by qualified skilled person(electrician).
2. The local safety regulations and relevant operating procedures must be observed during the installation, operation and maintenance of the equipment, otherwise the equipment may get damaged. The safety precautions mentioned in the manual are only the supplement to local safety regulations.
3. We are more than happy to offer general advice about our products or solutions to an issue you may have. However as we have limited knowledge of your actual system this advise is generic and therefore given on the understanding that we cannot be held accountable for any damaged caused.

 

Caution

1. Do not dispose of batteries in fire. The batteries may explode.
2. Do not open or mutilate batteries. Released electrolyte can prove harmful to the skin and eyes. It may be toxic.
3. A battery can present a risk of electric shock and burns by high short-circuit current.
4. A malfunctioned battery can reach temperatures that exceed the threshold of contact surface.
The following precautions should be observed when working on batteries:
a) Disconnect the power and loads before connecting or disconnecting battery terminals;
b) Do not wear any metal objects including watches and rings;
c) Use tools with insulated handles;
d) Do not lay tools or metal parts on top of batteries;
e) Wear personal protective equipment.
f) Make sure the battery is well grounded.
Contact with any part of a poorly grounded or ungrounded battery can cause electric shock and burns by high short-circuit current.
The risk of such hazards can be reduced if conductive surroundings are removed by a skilled person during installation and maintenance.

Danger

1. Keep the Li-ion battery away from water, dust and contamination, otherwise it may cause explosion or other harmful conditions that may even lead to personal injury.
2. Do not short-circuit the Li-ion battery.
3. Observe the positive(+) and negative(-) marks on the Li-ion battery and equipment and ensure correct use. Do not reverse the Li-ion battery.
4. Do not dismantle, crush, puncture, open or shred the Li-ion battery.
5. Before removing or reconnecting with the running system, the power must be off and the system should be shut down, otherwise there will be risk of electric shock.
6. Do not expose Li-ion battery to heat or fire. In case of fire, please use dry powder fire extinguisher.
7. Do not dismantle any part of the system without contacting the manufacturers authorized technical engineers. System failure caused by such will not be covered by the warranty.
8. Before operating inverter, make sure that all batteries have been started up.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Other related products …

  • Victron GX Touch 50

    £230.00 Inc. VAT
  • Victron Lynx Shunt VE.Can

    £370.00 Inc. VAT
  • Victron Battery switch ON/OFF 275A

    £43.00 Inc. VAT
  • Victron Lynx Distributor (M10)

    £219.00 Inc. VAT